OPERATION & ADJUSTMENT
5
1. The compressor is controlled by a pressure switch. It can be
stopped automatically as the pressure increases to the maximum
and restarted as pressure decreases to the minimum. The rated
pressure has been adjusted during the manufacturing process -
do not alter it carelessly.
2. As soon as the motor is switched off the compressed air in the
discharge pipe should be released through the release valve
under the switch. This is a necessary condition before restarting
or the motor will be damaged.
3. The output pressure of compressed air can be regulated by using the
regulating valve. turn the regulation valve knob clockwise to
increase the pressure.
4. When the compressor needs to be stopped, set the power switch to
the ‘OFF’ position.
5. If the compressor should overheat, the Thermal Overload will
intervene and shut down the compressor. Should this happen, switch
OFF the machine by pushing the STOP/START switch downwards, and
wait for at least 5 minutes before pressing the red RESET button
underneath the air filter and try to start the compressor again.