Page 20
Section - 3
EMERGENCY PROCEDURES
FAA Approved
Revision A1: Mar 6, 2007
Hawker 850XP Pro Line 21 Airplane Flight Manual
ELECTRICAL FIRE OR SMOKE (continued)
Visually verify that any fire has been extinguished and land at the nearest suitable airport.
WARNING: FLIGHT TIME IS LIMITED WITH BOTH GENERATORS TRIPPED.
NOTE: If depressurized, the DUMP VALVE may be opened fully to improve smoke
clearance.
FUSELAGE FIRE OR SMOKE
Fire or smoke from cabin furnishings or equipment other than from electrical/electronic
sources.
NOTE: Headsets and hats must be removed before donning oxygen mask.
DUMP VALVE............................................................... OPEN slowly to assist smoke
clearance but maintain cabin
pressure.
One crew member don Protective Breathing Equipment (PBE) and use the hand-held fire
extinguisher to take appropriate action.
Visually verify that any fire has been extinguished and land at the nearest suitable airport.
SMOKE CEASES
Services may be re-instated individually as required.
Identify defective service and leave off.
Crew oxygen ......................................................Don masks - 100% EMERG
Mic selector ........................................................OXY- MIC
Cabin notices .....................................................ON