Errors 

 

‘Err’

 message 

 This is only displayed when in run mode and there is a problem with 
the relays. The most common cause is one or both of the relays ON and 
OFF points are the same. 

 

dp

 not blinking 

If the decimal point is not blinking the unit may have been 
unintentionally left in program mode. Press the 

‘M’

 key repeat until 

‘Fin’

 is displayed the press the 

‘E’

 key, this will exit programme mode 

 

 

Alternatively momentarily turn the power 

OFF

 and then back 

ON. 

 
 
 
 
Power Backup System 

Uninterrupted systems can be implemented using a backup battery, If a backup system is 
required it would be normal to specify a DC model. The normal configuration is to use 
18VDC to 24VDC derived from an AC power supply and a 12VDC external battery. When 
mains AC is present the Type 900 operates from the DC output  from the mains AC power 
supply, when the mains AC fails the Type 900 operates from the battery. It is essential to 
put a diode such as a IN4001 in series with each of the +V supplies to the 900, see diagram 
below. Optionally a solar panel could be used as well as a recharging system.  

NOTE:

 If power falls then it may be the case where the relay contacts lose their voltage 

too. Backup systems are useful where supplies are from different sources or the Type 900 
relays are used to drive other relays for control and indication. 

 

 

 

 

 
 

 

 
 
 
 
 