7. If not already applied, apply a single, short burst of corrosion inhibitor such as CorrosionX HD (P/N 222-0000-
020) to the NCV2 connection. Be sure the corrosion inhibitor has coated the NCV2 contacts and recessed
portions of the connector.
NOTE:
To determine whether corrosion inhibitor has been applied, inspect for a thick liquid in the bottom of
the connector as shown in the image below.
CorrosionX may also be purchased from the manufacturer website:
https://www.corrosionx.com/products/corrosionx-heavy-duty.
FIGURE 4. Applying Corrosion Inhibitor
NCV2
Connector
Corrosion Inhibitor