03/18
Model 7603BLH/7603BL240H
Page 5 of 7
STEP 8:
Attach grounding clamp to tank handle. Attach second ground clamp around metal
hub on the junction box. Connect the two ground clamps with the supplied grounding
wire.
STEP 9:
Attach conical top blanket with Velcro closures. Align the seam of the top blanket with
the push flag. The electrical cord may exit across the Velcro seem at any location.
IMPORTANT SAFETY NOTICE
THE NATIONAL ELECTRICAL CODE REQUIRES GROUND-FAULT EQUIPMENT PROTECTION ON EACH
HEATING CABLE BRANCH CIRCUIT. TO REDUCE THE RISK OF FIRE CAUSED BY DAMAGE OR IMPROPER
INSTALLATION, CIRCUIT BREAKERS SUCH AS SQUARE D QO-EPD AND QOB-EPD OR EQUIVALENT, WITH
A 30mA TRIP LEVEL, SHOULD BE USED. PLEASE SUBSTITUTE THESE BREAKERS WHEREVER
REFERENCE IS MADE TO CONVENTIONAL BREAKERS IN THIS DOCUMENT. ALTERNATIVE DESIGNS
PROVIDING COMPARABLE LEVELS OF GROUND-FAULT PROTECTION MAY ALSO BE ACCEPTABLE.