TROUBLE SHOOTING & MAINTENANCE
Temperature Control
: Factory set at 5° (50°F) under normal conditions. For colder water, adjust screw
on item no. 12 in clockwise direction.
Ventilation
: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or
vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on
the compressor overload protector.
Lubrication
: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings:
Cooler is provided with lead-free connectors which utilize
an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while
pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop,
approximately 3/4".