background image

HAWS AG 

x

 Bachweg 3 

x

 CH-3401 Burgdorf 

x

Switzerland 

x

 www.haws.ch

HAWS Corporation 

x

 P.O.Box 2070 

x

 1455 Kleppe Lane 

x

 Sparks,Nevada 89431/USA 

x

 www.hawsco.com

HAWS DRINKING FAUCET COMPANY

FITTINGS AND OPERATING INSTRUCTIONS

2075001

-

-

-

-

HCR8.50

Jeannine Ruf

04.03.2013

3/3

No.

Model 

HCR8.50      

Remote Chiller 220Volt

TROUBLE SHOOTING & MAINTENANCE

Temperature Control

: Factory set at 5° (50°F) under normal conditions. For colder water, adjust screw

on item no. 12 in clockwise direction.

Ventilation

: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or

vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on

the compressor overload protector.

Lubrication

: Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings:

 Cooler is provided with lead-free connectors which utilize

an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while 

pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop,

approximately 3/4".