background image

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16

17

18
19

2
2
1
1
1
2
1
1
1
1
1
1
1
1
4
4

1

2
1

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1600AA
SPX1600R
SPX2600B
SPX2600C
SPX1600Z2
SPX1600T
SPX2600E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1600Z1M

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1600AA
SPX1600R
SPX2600B
SPX2605C
SPX1600Z2
SPX1600T
SPX2600E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1605Z1M

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1600AA
SPX1600R
SPX2600B
SPX2607C
SPX1600Z2
SPX1600T
SPX2600E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1607Z1M

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1600AA
SPX1600R
SPX2600B
SPX2610C
SPX1600Z2
SPX1600T
SPX2600E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1610Z1M

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1620AA
SPX1600R
SPX2600B
SPX2615C
SPX1600Z2
SPX1600T
SPX2600E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1615Z1M

SPX1600P
SPX1600N
SPX1600D
SPX1600S
SPX1600M
SPX4000P
SPX1620AA
SPX1600R
SPX2616B
SPX2621C
SPX1600Z2
SPX1600T
SPX1611E5
SPX1600F5
SPX1600Z4
SPX0125Z4

SPX2600G1

SPX1600Z5
SPX1620Z1M

REF.

NO.

DESCRIPTION

NO.

REQ’D

MODEL

SP2600X5

MODEL

SP2605X7

MODEL

SP2607X10

MODEL

SP2610X15

MODEL

SP2615X20

MODEL

SP2621X25

Hand Knob
Swivel Nut
Strainer Cover
Strainer Cover Gasket
Basket
Drain Plug w/Gasket
Pump Housing/Strainer

Gasket

Impeller
Seal Assembly
Housing Gasket
Seal Plate
Motor Mounting Plate
Housing Cap Screw
Motor Cap Screw
Mounting Base w/   Adapter  

and Screws
Mounting Foot Cap Screw
Motor-60 Cycle Single  Phase 

PAR

T NUMBER

6

7

8

9

4

3

2

1

10

11

16

12

13

15

14

19

5

SPx2600Q

Mounting Adapter.
Optional with
some motors.

NOTE: 

 For 60 cycle 3 phase or 50 cycle motors — Consult Factory, giving HP, Cycle and Phase.

17

18

Haywardpool.ca

Summary of Contents for SP2600X5

Page 1: ...ubricant for the mechanical shaft seal Open all suction and discharge valves as well as air displaced from the suction line must have someplace to go Turn on power and allow a reasonable time for prim...

Page 2: ...X1610Z1M SPX1600P SPX1600N SPX1600D SPX1600S SPX1600M SPX4000P SPX1620AA SPX1600R SPX2600B SPX2615C SPX1600Z2 SPX1600T SPX2600E5 SPX1600F5 SPX1600Z4 SPX0125Z4 SPX2600G1 SPX1600Z5 SPX1615Z1M SPX1600P S...

Page 3: ...he motor mounting bracket Press the ceramic seat with o ring out of the seal plate If tight use a small screwdriver to tap seat out STOP Clean all recesses and parts to be reassembled Inspect gaskets...

Page 4: ...ld up due to an improper operating condition can occur The motor will auto restart when safe heat level is reached Check for Centrifugal switch stuck in open position Binding of motor shaft water and...

Page 5: ...a cr pine le b ti d eau jusqu au niveau du tuyau de succion Ne jamais mettre la pompe en marche vide L eau m canique Ouvrir toutes les soupapes de succion et de d charge ainsi du conduit de succion do...

Page 6: ...SPX1600M SPX4000P SPX1600AA SPX1600R SPX2600B SPX2600C SPX1600Z2 SPX1600T SPX2600E5 SPX1600F5 SPX1600Z4 SPX0125Z4 SPX2600G1 SPX1600Z5 SPX1600Z1M SPX1600P SPX1600N SPX1600D SPX1600S SPX1600M SPX4000P S...

Page 7: ...er sur le si ge en c ramique muni d un joint torique pour le sortir de la plaque d tanch it S il est trop serr utiliser un petit tournevis et frapper l g rement le si ge jusqu ce qu il sorte PAUSE Net...

Page 8: ...tiquement en marche d s que la temp rature est revenue la normale Commutateur de la centrifugeuse coinc en position ouverte Coincement de l arbre du moteur Vous assurer que la cr pine de la pompe est...

Reviews: