USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
Mounting the AQR100 Control Box
The AQR100 is contained in a raintight enclosure that is suitable for outdoor mounting. The Control
Box must be mounted a minimum of 10 ft. (4 meters) horizontal distance (or more, if local codes
require) from the pool and within 15 ft. from where the Cell is installed.
The Control Box is designed to mount vertically on a flat surface with the cables facing downward.
Because the enclosure also acts as a heat sink (disperses heat from inside the box), it is important
not to block the four sides of the Control Box. Do not mount the Control Box inside a panel or tightly
enclosed area.
Before securing the Control Box to the intended location, make sure that the Cell cable will reach the
location where the Cell Vessel will be installed. For mounting information, refer to the diagram below.
Select appropriate fasteners for your mounting surface that are suitable for a 20lb load. The mounting
template shown in Step 1 can be found on page 18.
Screw in top
fasteners leaving
1/8” space between
screw head and surface
Attach top mounting hole
guide to desired location and
drill mounting holes.
Hang Control Box
on fasteners and drill
bottom holes.
Screw in bottom
fasteners securely.
1
3
2
4
Located in
back of Manual