ELECTROLYTIC CHLORINE GENERATOR
BASIC POOL MAINTENANCE REQUIREMENTS
Free Chlorine
1.0 - 3.0 ppm
pH
7.2 - 7.6
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too low - add soda ash.
Too high - add muriatic acid
Alkalinity
80 - 120 ppm
Salt
2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer
20 - 30 ppm
Add cyanuric acid to increase.
Calcium
200 - 400 ppm
Add calcium to increase.
Electrolytic Cell inspect & clean
Refer to section in manual.
TEST
IDEAL RANGE
ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.
WEEKL
Y
MONTHL
Y
QUAR
TTERL
Y
17
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS