or death.  Before servicing pool and spa water circulation system, all system and pump controls 

must be in off position and filter manual air relief valve must be in open position.  Before starting 

system pump, all system valves must be set in a position to allow system water to return back to 

the pool.  Do not change filter control valve position while system pump is running.  Before starting 

system pump, fully open filter manual air relief valve.  Do not close filter manual air relief valve until 

a steady stream of water (not air or air and water) is discharged.

WARNING – Separation Hazard  

Failure to follow safety and operation instructions could 

result in violent separation of pump and/or filter components.  Strainer cover must be properly 

secured to pump housing with strainer cover lock ring.  Before servicing pool and spa circulation 

system, filters manual air relief valve must be in open position.  Do not operate pool and spa circu-

lation system if a system component is not assembled properly, damaged, or missing.  Do not oper-

ate pool and spa circulation system unless filter manual air relief valve body is in locked position in 

filter upper body.  Never operate or test the circulation system at more than 50 PSI.  Do not purge 

the system with compressed air.  Purging the system with compressed air can cause components 

to explode, with risk of severe injury or death to anyone nearby.  Use only a low pressure (below 5 

PSI), high volume blower when air purging the pump, filter, or piping.

WARNING – Risk of Electric Shock

  All electrical wiring MUST be in conformance with ap-

plicable local codes, regulations, and the National Electric Code (NEC).  Hazardous voltage can 

shock, burn, and cause death or serious property damage.  To reduce the risk of electric shock, do 

NOT use an extension cord to connect unit to electric supply.  Provide a properly located electrical 

receptacle.    Before working on any electrical equipment, turn off power supply to the equip-

ment.  To reduce the risk of electric shock replace damaged wiring immediately.  Locate conduit 

to prevent abuse from lawn mowers, hedge trimmers and other equipment.   Do NOT ground to a 

gas supply line.

  

WARNING – Risk of Electric Shock 

 Failure to ground all electrical equipment can cause seri-

ous or fatal electrical shock hazard.  Electrical ground all electrical equipment before connecting 

to electrical power supply.  

  

WARNING – Risk of Electric Shock 

 Failure to bond all electrical equipment to pool structure 

will increase risk for electrocution and could result in injury or death.  To reduce the risk of electric 

shock, see installation instructions and consult a professional electrician on how to bond all elec-

trical equipment.  Also, contact a licensed electrician for information on local electrical codes for 

bonding requirements.

Notes to electrician: 

 Use a solid copper conductor, size 8 or larger.  Run a continuous wire from 

external bonding lug to reinforcing rod or mesh.  Connect a No. 8 AWG (8.4 mm

2

) [No. 6 AWG 

(13.3 mm

2

) for Canada] solid copper bonding wire to the pressure wire connector provided on the 

electrical equipment and to all metal parts of swimming pool, spa, or hot tub, and metal piping (ex-

cept gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool, spa, or hot tub.

IMPORTANT

 - Reference NEC codes for all wiring standards including, but not limited to, ground-

ing, bonding and other general wiring procedures.

  

WARNING – Risk of Electric Shock

  The electrical equipment must be connected only to a 

supply circuit that is protected by a ground-fault circuit-interrupter (GFCI).  Such a GFCI should 

be provided by the installer and should be tested on a routine basis.  To test the GFCI, push the 

test button.  The GFCI should interrupt power.  Push reset button.  Power should be restored.  If 

the GFCI fails to operate in this manner, the GFCI is defective.  If the GFCI interrupts power to the 

electrical equipment without the test button being pushed, a ground current is flowing, indicating 

the possibility of an electrical shock.  Do not use this electrical equipment.  Disconnect the electri-

cal equipment and have the problem corrected by a qualified service representative before using.

  

CAUTION

 – HAYWARD

®

 pumps are intended for use with permanently-installed pools and may be 

used with hot tubs and spas if so marked.  Do not use with storable pools.  A permanently-installed 

pool is constructed in or on the ground or in a building such that it cannot be readily disassembled 

for storage.  A storable pool is constructed so that it is capable of being readily disassembled for 

storage and reassembled to its original integrity.  

SAVE THESE INSTRUCTIONS

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

8

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Summary of Contents for ColorLogic

Page 1: ...Elizabeth NJ 07207 Phone 908 355 7995 www hayward com ColorLogic Pool Lamp Color LED Replacement Lamp Owner s Manual BPCUS11120 Contents Introduction 2 Installation 2 Operation 5 092759 RevA draft3 U...

Page 2: ...and followed The cord length has not been extended beyond the guidelines in this manual The cord jacket is not damaged cut or spliced except as noted below Extensions or splices to the cord are only...

Page 3: ...ols OmniLogic OmniHub Pro Logic ColorLogic Light Controller Installation Before You Begin Before attempting to install confirm that you have a compatible light fixture Disconnect power to the pool lig...

Page 4: ...e 3 Inspect fixture and remove old lamp While the fixture is out of the pool and the lens is off inspect the housing for wear or damage Do not install the BPCUS11120 into a fixture that may be prone t...

Page 5: ...scaping from the gasket area or at the power cord entrance If bubbles appear immediately remove the light fixture from the water and re seat the gasket and lens Continue the installation only if there...

Page 6: ...light off and then back on Continue this method until you arrive at the desired mode Note that Universal ColorLogic modes blinking red are repeated 4 times so it may take a few cycles to arrive at Omn...

Page 7: ...how Twilight 13 Show Tranquility 14 Show Gemstone 15 Show USA 16 Show Mardi Gras 17 Show Cool Cabaret Refer to the included color card as a quick reference to the available programs Omni Direct The BP...

Page 8: ...any suction outlet component is damaged broken cracked missing or not securely attached Replace damaged broken cracked missing or not securely attached suction outlet compo nents immediately In additi...

Page 9: ...electrical shock hazard Electrical ground all electrical equipment before connecting to electrical power supply WARNING Risk of Electric Shock Failure to bond all electrical equipment to pool structu...

Page 10: ...9 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS...

Page 11: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 10...

Page 12: ...ColorLogic is a trademark of Hayward Industries Inc 2019 Hayward Industries Inc All other trademarks not owned by Hayward are the property of their respective owners Hayward is not in any way affiliat...

Reviews: