background image

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

 

Page 8 of 16 

Max-Flo™ PUMP Series 

IS2800X5  Rev. C 

Storage/Winterization 

 

 

  

WARNING

 

 

Separation Hazard.  

Do not purge the system with compressed air.  Purging 

the system with compressed air can cause components to explode, with risk of severe injury or death to 
anyone nearby.  Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, 
filter, or piping. 

 

 

  

ATTENTION

 

 

Allowing the pump to freeze will void the warranty.

 

 

  

ATTENTION

 

 

Use ONLY propylene glycol as antifreeze in your pool/spa system.  Propylene glycol is non-

toxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components 
in the system.

 

 

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see 
instructions below).   

            

 

Keep motor dry and covered during storage.  To avoid condensation/corrosion problems, do NOT cover or wrap pump with 
plastic film or bags.

 

 
Storing Pump For Winterization

 

 

  

WARNING

 

 

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor 

before draining pump.  Failure to disconnect power may result in serious personal injury or death.

 

1.

 

Drain water level below all inlets to the pool. 

2.

 

Remove drain plugs from bottom of strainer body, and remove strainer cover from strainer housing. 

3.

 

Disconnect pump from mounting pad, wiring system (after power has been turned OFF), and piping 
system. 

4.

 

Once the pump is removed of water, re-install the strainer cover and drain plugs.  Store pump in a 
dry area. 

 
Shaft Seal Change Instructions 

 

IMPORTANT SAFETY INSTRUCTIONS 

PLEASE READ AND FOLLOW ALL INSTRUCTIONS 

 

When servicing electrical equipment, basic safety precautions should always be observed including the following.  Failure to follow 
instructions may result in injury. 

 

A.

 

  

WARNING 

– 

To reduce risk of injury, do not permit children to use this product. 

B.

 

Disconnect all electrical power service to pump before beginning shaft seal replacement. 

C.

 

Only qualified personnel should attempt rotary seal replacement.  Contact your local authorized Hayward Dealer or 
service center if you have any questions. 

 

Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal.  Foreign matter or 
improper handling will easily scratch the graphite and ceramic sealing surfaces. 

 

Removing the Motor Assembly  

(See Parts Diagram on page 10 of this manual for pump component locations.)

 

 

 

 

 

 

 

1.

 

Remove the four (4) 3/8" x 2" 

housing cap screws 

which hold the motor assembly to the 

pump/strainer 

housing

 
2.

 

Slide the motor assembly out of the 

pump/strainer housing

, exposing the 

diffuser

.  Pull the 

diffuser 

off of the 

seal plate

, exposing the 

impeller

.  (The 

diffuser

 may remain in the 

pump/strainer housing

.  To remove, pull 

it straight out of the 

pump/strainer housing

.) 

  

Summary of Contents for Max-Flo SP2805X7

Page 1: ...in ground swimming pool spa that is equipped with large capacity filters heaters and pool cleaning equipment The Max Flo is a self priming pump that incorporates an improved seal and impeller design t...

Page 2: ...ely attached suction outlet components immediately o In addition two or more suction outlets per pump installed in accordance with latest ASME APSP Standards and CPSC guidelines follow all National St...

Page 3: ...uipment can cause serious or fatal electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to all electrical equipment be...

Page 4: ...actical and run suction lines as direct as possible to reduce friction loss Suction lines should have continuous slope upward from lowest point in line Joints must be tight but not over tightened Suct...

Page 5: ...the fitting beginning at the end of the fitting The pump suction and outlet ports have molded in thread stops Do NOT attempt to force hose connector fitting past this stop It is only necessary to tig...

Page 6: ...und terminal to electrical service ground Bond motor to pool structure Bonding will connect all metal parts within and around the pool with a continuous wire Bonding reduces the risk of a current pass...

Page 7: ...pump and piping system using filter manual air relief valve See filter owner s manual for more details 4 If water source is higher than the pump pump will prime itself when suction and outlet valves...

Page 8: ...cover from strainer housing 3 Disconnect pump from mounting pad wiring system after power has been turned OFF and piping system 4 Once the pump is removed of water re install the strainer cover and d...

Page 9: ...t locations 8 Clean and lightly lubricate the impeller hub and seal recess in the seal plate with a dilute solution of non granulated liquid type soap 9 Gently wipe the black polished surface of the s...

Page 10: ...1 SPX1600R SPX1600R SPX1600R SPX1600R SPX1600R 8 DIFFUSER 1 SPX2800B SPX2800B SPX2800B SPX2800B SPX2800B 9 IMPELLER 1 SPX2605C SPX2607C SPX2610C SPX2615C SPX2610C 10 SEAL ASSEMBLY 1 SPX1600Z2 SPX1600Z...

Page 11: ...ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is locked firmly in position Lubricant will help to creat...

Page 12: ...d suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction condition or throttle return lines if practical Holding hand over return fi...

Page 13: ...r the nearest Hayward Authorized Service Center For assistance on your nearest Hayward Authorized Service Center please visit us at www haywardpool com Hayward shall not be responsible for cartage rem...

Page 14: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 14 of 16 Max Flo PUMP Series IS2800X5 Rev C THIS PAGE INTENTIONALLY LEFT BLANK...

Page 15: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 15 of 16 Max Flo PUMP Series IS2800X5 Rev C THIS PAGE INTENTIONALLY LEFT BLANK...

Page 16: ...tions Mail to Hayward Pool Products 620 Division Street Elizabeth NJ 07207 Attn Warranty Dept Or REGISTER YOUR WARRANTY ON LINE AT WWW HAYWARDNET COM DETACH HERE Fill out bottom portion completely and...

Reviews: