background image

www.haywardpool.com              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Max-Flo II

 ™

 Series __________________                   ___________________________       ___Page 10 of 16 

 

 

10.  Gently wipe the black, polished surface of the spring seal assembly with a clean, soft, cotton cloth.   
11.  Press the spring seal assembly (item #12) onto the motor shaft – black polished surface facing toward the 

polished surface of the ceramic seat. 

 

Replacing the Impeller and Diffuser  

(See Parts Diagram on page 11 of this manual for pump component locations.) 

 
11.  Screw the impeller (item#10) onto the motor shaft in a clockwise direction.  Tighten snugly by holding motor 

shaft with wrench as noted in step #4.   

 

12.  Place the diffuser (item #9) over the impeller (item#10) onto the seal plate (item#13), aligning the three (3) 

protruding pins with the matching holes in the seal plate (item#13).  Note:  Arrow on diffuser (item #9) will 
face up.  Replace two diffuser screws (item #7). 

 

 

Replacing the Motor Assembly

  (See Parts Diagram on page 11 of this manual for pump component locations.)

 

 

14.  Re-attach motor end cover/canopy by using the two (2) hex shaped screws.  Slide the motor assembly with the 

diffuser (item#9) in place, into pump/strainer housing (item#4), being careful not to disturb the diffuser gasket 
(item#8). 

 

15.  Re-attach assembly to pump/strainer housing (item#4) using the four (4) 5/16”" x 1 3/4" hex head bolts.  (Be 

sure housing gasket (item#11) is in place, and lubricated.  Replace if damaged).  Tighten alternately and evenly 
to 185 in-lbs using torque pattern in diagram 1 at bottom of this page. 

 

 

Diagram 1

 

Summary of Contents for Max-Flo™

Page 1: ...122 degrees F an elevated base for improved motor cooling and to prevent flooding The Max Flo II is an ideal choice for both new construction or as a replacement pump To prevent potential injury and t...

Page 2: ...nnot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is...

Page 3: ...outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become ent...

Page 4: ...operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in loc...

Page 5: ...o meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free...

Page 6: ...s Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to...

Page 7: ...mming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All electrical wir...

Page 8: ...uction pipe If pump does NOT prime within five minutes stop motor and determine cause Be sure all suction and discharge valves are open when pump is running See Troubleshooting Guide ATTENTION Wait fi...

Page 9: ...4 exposing the diffuser item 9 Remove the two diffuser screws item 7 and pull the diffuser off of the seal plate item 13 to expose the impeller item 10 Removing the Impeller See Parts Diagram on page...

Page 10: ...the diffuser item 9 over the impeller item 10 onto the seal plate item 13 aligning the three 3 protruding pins with the matching holes in the seal plate item 13 Note Arrow on diffuser item 9 will face...

Page 11: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series __________________ ____________________________ Page 11 of 16 Replacement Parts Parts Diagram SEE PARTS LISTING ON NEXT PAGE Item 16 Option...

Page 12: ...thru 1 HP 1 SPX2700BE Diffuser 2 HP 1 10 SPX2700C Impeller for HP Max Rate Pump 10 SPX2707CM Impeller for 1 HP Max Rate Pump 10 SPX2710CM Impeller for 1 HP Max Rate Pump 10 SPX2715CM Impeller for 2 HP...

Page 13: ...mp strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is lo...

Page 14: ...ir leak in suction piping cavitations caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction cond...

Page 15: ...g the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective...

Page 16: ...www haywardpool com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series ___ Page 16 of 16 This Page is Blank...

Reviews: