background image

www.haywardpool.com              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Max-Flo II

 ™

 Series ____             ____                                           _____                                    _     Page 2 of 16 

     

IMPORTANT SAFETY INSTRUCTIONS 

 

Before installing or servicing this electrical equipment, turn power supply OFF.   

 

 

WARNING

 – 

Read and follow all instructions in this 

owner’s manual and on the equipment.  Failure to follow 
instructions can cause severe injury and/or death. 

 

 

 
 

 

WARNING –

 

This product should be installed and serviced only by a qualified professional.

 

 

CAUTION –

 

All electrical wiring MUST be in conformance with all applicable local codes, regulations, and the 

National Electric Code (NEC).

 

 

Use of non-Hayward replacement parts voids warranty. 

 

ATTENTION INSTALLER – THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE 
INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER 
OF THIS PRODUCT.  FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS 
INJURY.

 

 

 

 

WARNING

 – 

To reduce risk of injury, do not permit children to use or climb on this product.  Closely supervise children 

at all times.  Components such as the filtration system, pumps, and heaters must be positioned to prevent children from using them as a 
means of access to the pool.

 

 

 

CAUTION

 – 

This pump is intended for use on permanently installed swimming pools and may also be used with hot tubs 

and spas if so marked.  Do NOT use with storable pools.  A permanently installed pool is constructed in or on the ground or in a 
building such that it cannot be readily disassembled for storage.  A storable pool is constructed so that it is capable of being readily 
disassembled for storage and reassembled to its original integrity.  
 
Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the weather.  Select a 
well-drained area, one that will not flood when it rains.  It requires free circulation of air for cooling.  Do not install in a damp or non-
ventilated location.  If installed within an outer enclosure or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation 
of air must be provided to prevent overheating of the motor. 
 

 

WARNING

 – 

Pool and spa components have a finite life.  All components should be inspected frequently and replaced at 

least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached. 

Basic safety precautions should always be followed, including the following: Failure to follow instructions may 
result in injury. 

 

 

This is the safety-alert symbol. When you see this symbol on your pump or in this manual, look for one of the 

following signal words and are alert to the potential for personal injury.

 

 

 

WARNING 

warns about hazards that 

could 

cause serious personal injury, death or major property 

damage and if ignored presents a potential hazard. 

 

 

CAUTION 

warns about hazards that 

will 

or 

can 

cause minor or moderate personal injury and/or property 

damage and if ignored presents a potential hazard.  It can also make consumers aware of actions that are 
unpredictable and unsafe.   
 
The 

NOTICE 

label indicates special instructions that are important but not related to hazards. 

Summary of Contents for Max-Flo™

Page 1: ...122 degrees F an elevated base for improved motor cooling and to prevent flooding The Max Flo II is an ideal choice for both new construction or as a replacement pump To prevent potential injury and t...

Page 2: ...nnot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is...

Page 3: ...outlets and or suction outlet covers which are damaged broken cracked missing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become ent...

Page 4: ...operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in loc...

Page 5: ...o meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free...

Page 6: ...s Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to...

Page 7: ...mming pool spa or hot tub and to all electrical equipment metal piping except gas piping and conduit within 5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All electrical wir...

Page 8: ...uction pipe If pump does NOT prime within five minutes stop motor and determine cause Be sure all suction and discharge valves are open when pump is running See Troubleshooting Guide ATTENTION Wait fi...

Page 9: ...4 exposing the diffuser item 9 Remove the two diffuser screws item 7 and pull the diffuser off of the seal plate item 13 to expose the impeller item 10 Removing the Impeller See Parts Diagram on page...

Page 10: ...the diffuser item 9 over the impeller item 10 onto the seal plate item 13 aligning the three 3 protruding pins with the matching holes in the seal plate item 13 Note Arrow on diffuser item 9 will face...

Page 11: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series __________________ ____________________________ Page 11 of 16 Replacement Parts Parts Diagram SEE PARTS LISTING ON NEXT PAGE Item 16 Option...

Page 12: ...thru 1 HP 1 SPX2700BE Diffuser 2 HP 1 10 SPX2700C Impeller for HP Max Rate Pump 10 SPX2707CM Impeller for 1 HP Max Rate Pump 10 SPX2710CM Impeller for 1 HP Max Rate Pump 10 SPX2715CM Impeller for 2 HP...

Page 13: ...mp strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strainer cover is lo...

Page 14: ...ir leak in suction piping cavitations caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Correct suction cond...

Page 15: ...g the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective...

Page 16: ...www haywardpool com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Max Flo II Series ___ Page 16 of 16 This Page is Blank...