background image

SEAL CHANGE  INSTRUCTIONS

SP1500  SERIES

GENERAL

Exercise extreme care in handling and installing the new seal and ceramic seat assembly.

The lapped and polished surfaces may easily be damaged by dirt or scratching.

Shut off electrical power before performing service or maintenance.

Remove pump and motor assembly from piping
system.

Remove pump housing cover (with strainer
attached) by removing the seven (7) housing
bolts and nuts which fasten housing cover to
pump housing. The impeller is now exposed.

To remove impeller, insert screwdriver in slot at
end of motor.* Hold screwdriver so as to keep
shaft from turning, and rotate the impeller in a
counterclockwise direction. The spring portion of
the seal assembly is now exposed.

Note carefully the position of the spring seal and
pull it off the impeller.

To remove the stationary (ceramic seat) part of
the seal assembly:

a. Loosen the four (4) motor securing bolts and

disengage the motor from the pump housing.

b. With motor removed, press the clear plastic

and ceramic seat assembly out of the pump
housing recess.  If tight, tap lightly from the
“motor” side.

Clean and lubricate the impeller hub shaft and
pump housing seal recess with a dilute solution of
non-granulated liquid-type soap. Gently wipe the
polished face of the new ceramic seat with a soft,
dry cotton cloth.

Press the new spring portion of the assembly
onto the impeller, black polished surface facing
away from the impeller.

Carefully press ceramic seat, with O-ring, into
clear plastic seat retainer—polished surface
facing out. Be sure O-ring is in place on cut ridge
of clear plastic retainer. Press plastic retainer,
with ceramic seat inside, into recess of pump
housing—O-ring end first. Replace the assembly
firmly and evenly.

Carefully insert the motor shaft through the seal
assembly, and secure motor to pump housing
with four (4) motor securing bolts. (Be sure motor
base is positioned properly.)

Screw the impeller, with spring seal, onto the
motor shaft, hand tight by turning clockwise.

Clean flat gasket (replace if necessary) and
fasten housing cover to pump housing with seven
(7) bolts and nuts. Tighten bolts and nuts
alternately and evenly.

Reconnect pump to piping system.  Be sure to fill
strainer with water before restarting.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

*For A.O. Smith Motors: Remove motor end cover and 

carefully apply wrench to flat on motor shaft to hold shaft from turning.

ELECTRICAL GUIDE — 60 CYCLE MOTORS — SINGLE PHASE

RECOMMENDED

WIRE SIZE

0-50’

BRANCH

FUSETRON

RATINGS—AMPS

CIRCUIT BREAKER

RATINGS—AMPS

VOLTS

MOTOR

KW

1.1

HP

1-1/2

115

20

20

No. 12

A separate electrical circuit, utilizing a rating as above, is recommended.

Reviews: