background image

OWNER’S MANUAL 

INSTALLATION, OPERATION & PARTS 

 

 

SAVE THIS INSTRUCTION MANUAL 

 
 
 
 

 
 

IS270T-05

 

Rev. B

 

MODEL S270T  PRO

 SERIES HIGH-RATE SAND FILTER 

Basic safety precautions should always be followed, including the following: Failure to follow instructions can cause severe 
injury and/or death. 

 

 

This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the 

following signal words and be alert to the potential for personal injury.

 

 

 

WARNING 

warns about hazards that 

could 

cause serious personal injury, death or major property damage and if 

ignored presents a potential hazard.

 

 

 

CAUTION 

warns about hazards that 

will 

or 

can 

cause minor or moderate personal injury and/or property damage 

and if ignored presents a potential hazard.  It can also make consumers aware of actions that are unpredictable and unsafe.

   

 

The 

NOTICE 

label indicates special instructions that are important but not related to hazards. 

HAYWARD POOL PRODUCTS, INC. 

620 Division Street     Elizabeth, NJ 07207     Tel: 908-351-5400 

WWW.HAYWARDPOOL.COM

 

Use only High Rate Sand No. ½ Silica Sand (.45mm - .55mm) 

Summary of Contents for Pro Series Top-Mount

Page 1: ...al for personal injury WARNING warns about hazards that could cause serious personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that w...

Page 2: ...suction outlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and othe...

Page 3: ...ce the filter 1 The filter system should be installed not more than 6 feet above pool water level on a level concrete slab very firm ground or equivalent as recommended by your pool dealer Position th...

Page 4: ...egular vacuuming BACKWASH For cleaning filter When filter pressure gauge rises 8 10 PSI 0 55 0 69 BAR above start up clean pressure Stop the pump set valve to BACKWASH Start pump and backwash until wa...

Page 5: ...TS REQUIRED CLEARANCE MEDIA REQUIRED EFFECTIVE FILTRATION AREA MAXIMUM WORKING PRESSURE SIDE ABOVE TYPE AMOUNT MODEL NUMBER FT 2 M 2 PSI BAR INCH MM INCH MM FILTER SAND LBS KG S270T 3 7 35 50 3 45 18...

Page 6: ...POOL CHEMISTRY SUGGESTED POOL CHEMISTRY LEVELS TO RAISE TO LOWER pH 7 2 to 7 6 Add Soda Ash Add Muriatic Acid or Sodium Bisulphate TOTAL ALKALINITY 100 to 130 ppm Add Sodium Bicarbonate Add Muriatic...

Page 7: ...hich fail or become defective during the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 9...

Page 8: ...Page 8 of 8 MODEL S270T IS270T 05 Rev B WWW HAYWARDPOOL COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS THIS PAGE LEFT BLANK...

Reviews: