background image

 
 

 
 

USE ONLY HAYWARD GENUINE REPLACEMENT 

PARTS 

    

7

 

 

Start-Up & Operation 

 

WARNING

 

– Separation Hazard

 

Failure to Open all suction and discharge valves could result in severe 

personal injury.  To avoid OPEN all suction and discharge valves, as well as filter air relief valve (if available) on 
filter, when starting the circulating pump system.   

Starting/Priming the Pump: 

Pumps with single speed motors are self priming to 10 ft. and pumps with 2 speed motors are self priming to 10 ft. on 
high speed only.  Fill strainer housing with water to suction pipe level.  If water leakage occurs from anywhere on the 
pump or filter,  DO NOT start the pump.  If no leakage occurs, stand at least 10 feet from pump and/or filter and 
proceed with starting the pump.   

 

WARNING

 

– Separation Hazard - Failure to do wait to close filter manual air relief valve until a steady stream 

of water (not air or air and water) is discharged from valve could result in severe personal injury. To avoid wait 
for a steady stream of water.

 

NOTICE

 

 

NEVER OPERATE THE PUMP WITHOUT WATER.  Water acts as a coolant and lubricant for the mechanical 

shaft seal.  NEVER

 

run pump dry.

  

Running pump dry may damage seals, causing leakage, flooding, and voids 

warranty.  Fill strainer housing with water before starting motor. 

NOTICE –

 Do NOT add chemicals to pool/spa system directly in front of pump suction.  Adding undiluted 

chemicals may damage pump and voids warranty.

 

NOTICE 

 

Before removing strainer cover:

 

1.

 

STOP

 

PUMP before proceeding. 

2.

 

CLOSE VALVES in suction and outlet pipes. 

3.

 

RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve.  See filter 
owner’s manual for more details. 

4.

 

If water source is higher than the pump, pump will prime itself when suction and outlet valves are 
opened.  If water source is lower than the pump, unscrew and remove strainer cover; fill strainer 
housing with water. 

5.

 

Clean and lubricate strainer cover O-ring with "Jack's 327" each time it is removed.  Inspect O-ring and 
re-install on strainer cover. 

6.

 

Replace strainer cover on strainer housing; turn strainer cover hand knobs clockwise to tighten cover. 
NOTE - Tighten strainer cover knobs by hand only (no wrenches). 

7.

 

OPEN VALVES in suction and outlet pipes. 

Before re-starting pump, see “Starting/Priming the Pump” instructions.      

NOTICE

 

 

Wait five (5) seconds before re-starting pump.  Failure to do so may cause reverse rotation of motor and 

consequent serious pump damage. 

Turn on power and wait for pump to prime, which may take up to ten (10) minutes.  Priming time will depend on 
vertical length of suction lift and horizontal length of suction pipe. If pump does NOT prime within five minutes, stop 
motor and determine cause.  Be sure all suction and discharge valves are open when pump is running.  See 
Troubleshooting Guide. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Super Pump Series

Page 1: ...us personal injury death or major property damage and if ignored presents a potential hazard CAUTION warns about hazards that will or can cause minor or moderate personal injury and or property damage...

Page 2: ...ibed above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material can result in an increase potential for suction entrapment as described a...

Page 3: ...ground current is flowing indicating the possibility of an electrical shock Do not use this electrical equipment Disconnect the electrical equipment and have the problem corrected by a qualified servi...

Page 4: ...bris loads Exclusive swing aside hand knobs make strainer cover removal simple and easy See thru strainer cover lets you see when the basket needs cleaning All components molded of corrosion proof rei...

Page 5: ...gth Pipe Sizing Chart MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size Flow rate Water Velocity Pipe Size Flow rate Water Velocity inches mm GPM Liter Min ft sec meters sec inches mm GPM Li...

Page 6: ...oltage or components may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when pump is running at full load consult the power...

Page 7: ...ls to pool spa system directly in front of pump suction Adding undiluted chemicals may damage pump and voids warranty NOTICE Before removing strainer cover 1 STOP PUMP before proceeding 2 CLOSE VALVES...

Page 8: ...Pump for Winterization WARNING Electrical Hazard Failure to disconnect power may result in serious personal injury or death To avoid turn OFF power to motor before draining pump 1 Drain water level be...

Page 9: ...ly lubricate the impeller hub and seal recess in the seal plate with a dilute solution of non granulated liquid type soap 9 Gently wipe the black polished surface of the spring seal assembly with a cl...

Page 10: ...00C SPX2605C SPX2607C SPX2607C 11 SEAL ASSEMBLY 1 SPX1600Z2VIT SPX1600Z2 SPX1600Z2 SPX1600Z2 SPX1600Z2 12 HOUSING GASKET 1 SPX1600T SPX1600T SPX1600T SPX1600T SPX1600T 13 SEAL PLATE 1 SPX2600E5 SPX260...

Page 11: ...on Make sure pump strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring is lubricated with Jack s 327 and that strai...

Page 12: ...Pump Check For 1 Air leak in suction piping cavitation caused by restricted or undersized suction line or leak at any joint low water level in pool and unrestricted discharge return lines Solution Co...

Page 13: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 13 This page left blank intentionally...

Page 14: ...Hayward Authorized Service Center please visit us at www hayward com Hayward shall not be responsible for cartage removal repair or installation labor or any other such costs incurred in obtaining wa...

Page 15: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 15...

Page 16: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 16 is a registered trademark and Super Pump is a trademark of Hayward Industries Inc 2021 Hayward Industries All rights reserved...

Reviews: