USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 16 of 36
2.70 THP VS Pump Family
IS3206VSP3 Rev-B
DIP SWITCH STATUS
PUMP ADDRESS
#1
#2
#3
#4
#5
Pool Filter OFF
OFF
OFF
OFF
OFF
Aux 1 / Spa Filter OFF
ON
OFF
OFF
OFF
Aux 2
OFF
OFF
ON
OFF
OFF
Aux 3
OFF
ON
ON
OFF
OFF
Aux 4
OFF
OFF
OFF
ON
OFF
Aux 5
OFF
ON
OFF
ON
OFF
Aux 6
OFF
OFF
ON
ON
OFF
Aux 7
OFF
ON
ON
ON
OFF
Aux 8
OFF
OFF
OFF
OFF
ON
Aux 9
OFF
ON
OFF
OFF
ON
Aux 10
OFF
OFF
ON
OFF
ON
Aux 11
OFF
ON
ON
OFF
ON
Aux 12
OFF
OFF
OFF
ON
ON
Aux 13
OFF
ON
OFF
ON
ON
Aux 14
OFF
OFF
ON
ON
ON
Lights Button
OFF
ON
ON
ON
ON
5.3.
External Relay Speed Control Wiring (Optional, for remote selection of pump speed)
Note: For third party controls and Hayward controls that are NOT software compatible.
Figure 5.3-1
Connection wire must be rated for a minimum of 300V. Inputs are rated to accept a low voltage supply of 18-30 VAC,
9-30 VDC, 50/60 Hz. The “+12V” and “COM” terminals may be used as a low voltage supply, however, these
terminals also supply power to the user interface, so care must be taken when connecting to these terminals to
ensure proper operation of the user interface. DIP switch #1 must be “ON”.