USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 24 of 36
2.70 THP VS Pump Family
IS3206VSP3 Rev-B
Buttons
Screen Used
Comments
21.
+ -
Use + to reset to factory default settings
< >
Use > to skip reset
22.
+ -
Confirm reset of all parameters
< >
Move to next menu item
23.
6.7.
Timer Menu
Buttons
Screen Used
Comments
1.
< >
Use > to enter Timer Menu
2.
3.
4.
+ -
Use + to change displayed timer
< >
Use > to skip to next timer
5.
+ -
Use + to rename timer
< >
Use > to set motor speed for timer
6.
+ -
Use to set speed for timer
< >
Use > to set start/stop time
7.
+ -
Use to set start/stop time for timer
< >
Use > to choose days of operation for timer
8.
+ -
Use to choose days of operation for timer
< >
Move to next menu item
Note:
When start/stop times are set to be the same, the timer is deactivated. Each timer can be set to run on
specific days of the week. Options are to run 7 days per week, 5 days per week (Monday thru Friday), or on a single
day (Monday thru Sunday). Each timer is set up in this same manner. If the timers are set up such that their run
times overlap, the timers will run in priority from Timer 1 to Timer 8. In other words, if Timer 1 is set to run from 8:00
am to 12:00 pm, and Timer 2 is set to run from 10:00 am to 2:00 pm, the pump will run Timer 1 from 8:00 am to 12:00
pm, and will then switch to run Timer 2 until 2:00 pm. Default setting for Timer 1 is to start at 12:00 am, and end at
11:45 pm. When Remote Control Mode is set to Relay Control, the speed for Timer 1 may be set to 0 rpm to allow the
pump to be stopped without having to remove power.
Timer Menu
Press > to enter
Timer 1
1725rpm
12:00a to 11:45p
Press + to change
or > next timer
T1: Timer 1
+/- rename; speed >
Timer 1
1725rpm
+/- adjust; times >
Timer 1
1725rpm
8:00a to 6:00p
Choose Days
7D 7 days a week
Reset all settings?
+ yes or - no
Use Timers Menu to
set daily timers
Are you sure?
+ yes or - no
Press +/- to change
or > view next item