This control was inspected before shipment from our plant.  To original purchasers of this control, Hayward Pool 
Products, 620 Division Street, Elizabeth, New Jersey, warrants its products to be free from defects in materials and 
workmanship for a period of

ONE (1)

year from the date of purchase. 

Parts which fail or become defective during the warranty period, except as a result of freezing, negligence, improper 
installation, use, or care, shall be repaired or replaced, at our option, without charge, within 90 days of the receipt of 
defective product, barring unforeseen delays. 

To obtain warranty replacements or repair, defective components or parts should be returned, transportation paid, to 
the place of purchase, or to the nearest authorized Hayward service center.  For further Hayward dealer or service 
center information, contact Hayward customer service department.  No returns may be made directly to the factory 
without the express written authorization of Hayward Pool Products, Inc. 

All other conditions and terms of the standard warranty apply. 

Hayward shall not be responsible for cartage, removal and/or reinstallation labor or any other such costs incurred in 
obtaining warranty replacements. 

The Hayward Pool Products warranty does not apply to components manufactured by others.  For such products, the 
warranty established by the respective manufacturer will apply. 

Some states do not allow a limitation on how long an implied warranty lasts, or the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. 

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. 

This product is intended for use only with SP322063EEV pump.  Use with any other pump will void warranty.

 

Hayward Pool Products 
620 Division Street 

*Supersedes all previous publications. 

Elizabeth, NJ  07207

Summary of Contents for TriStar SP322063EEV

Page 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Page 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Page 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Page 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Page 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Page 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Page 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Page 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Page 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Page 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Page 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Page 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Page 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Page 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Page 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Page 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...