background image

WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

TriStar 

™ 

Waterfall Pump Series ___________                      _______________________ ______Page 2 of 15 

IMPORTANT SAFETY INSTRUCTIONS

 

Before installing or servicing this electrical equipment, turn power supply OFF.

 

WARNING

– Read and follow all instructions in this 

owner’s manual and on the equipment.  Failure to follow 
instructions can cause severe injury and/or death. 

WARNING –

This product should be installed and serviced only by a qualified professional.

 

CAUTION –

A licensed electrician MUST complete, in full, all electrical installations noted in this manual.

 

Use of non­Hayward replacement parts voids warranty. 

ATTENTION INSTALLER – THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, 
OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT. 
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY. 

WARNING 

 

To reduce risk of injury, do not permit children to use or climb on this product.  Closely supervise children 

at all times.  Components such as the filtration system, pumps, and heaters must be positioned to prevent children from using them as a 
means of access to the pool.

 

CAUTION 

 

This pump is intended for use on permanently installed swimming pools and may also be used with hot tubs 

and spas if so marked.  Do NOT use with storable pools.  A permanently installed pool is constructed in or on the ground or in a 
building such that it cannot be readily disassembled for storage.  A storable pool is constructed so that it is capable of being readily 
disassembled for storage and reassembled to its original integrity.  Though this product is designed for outdoor use, it is strongly 
advised to protect the electrical components from the weather.  Select a well­drained area, one that will not flood when it rains.  It 
requires free circulation of air for cooling.  Do not install in a damp or non­ventilated location.  If installed within an outer enclosure 
or beneath the skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of the 
motor.

WARNING 

 

Pool and spa components have a finite life.  All components should be inspected frequently and replaced at 

least every ten years, or if found to be damaged, broken, cracked, missing, or not securely attached.

 

TriStar 

™ 

Waterfall Pump Series ____        _____ 

________________________________Page 3 of 15

 

Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in injury. 

This is the safety­alert symbol. When you see this symbol on your pump or in this manual, look for one of the following 

signal words and be alert to the potential for personal injury.

 

WARNING

 

warns about hazards that

could

 cause serious personal injury, death or major property damage and if 

ignored presents a potential hazard.

 

CAUTION

 

warns about hazards that

will

 or

 can

 cause minor or moderate personal injury and/or property damage 

and if ignored presents a potential hazard.  It can also make consumers aware of actions that are unpredictable and unsafe. 

The

NOTICE

 label indicates special instructions that are important but not related to hazards.

Summary of Contents for TriStar SP36075EE

Page 1: ...ump for the pool water filtration sanitization system nor is it intended to be used in applications where water will be elevated more than 10 feet above the surface of the water in the pool NOTE To prevent potential injury and to avoid unnecessary service calls read this manual carefully and completely IMPORTANT READ CAREFULLY NOTE The TriStar Waterfall pump uses a low speed motor specifically des...

Page 2: ...ge A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electrical components from the weather Select a well drained area one that will not flood when it rains It requires free circulation of air for cooling Do not install in a da...

Page 3: ...sing or unsecured cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can become entangled in suction outlet cover Limb Entrapment A limb inserted into an opening of a suction outlet sump or suction outlet cover that is damaged broken cracked missing or not securely attached can result in a mechanical bind or swelling of the limb Body Suction Entrapment A ...

Page 4: ...in open position Do not operate pool and spa circulation system if a system component is not assembled properly damaged or missing Do not operate pool and spa circulation system unless filter air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and ...

Page 5: ...lean Pump motors require free circulation of air for cooling Pump Mounting Install pump on a firm level base or pad to meet all local and national codes Fasten pump to base or pad with screws or bolts to further reduce vibration and stress on pipe or hose joints The base MUST be solid level rigid and vibration free Pump mount must Allow pump inlet height to be as close to water level as possible A...

Page 6: ...t to force hose connector fitting past this stop It is only necessary to tighten fittings enough to prevent leakage Tighten fitting by hand and then use a tool to engage fitting an additional 1 turns Use care when using Teflon tape as friction is reduced considerably do NOT over tighten fitting or you may cause damage If leaks occur remove connector clean off old Teflon tape re wrap with one to tw...

Page 7: ...swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances are also on the same circuit be sure to add their amp loads before calculating wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch Install a Ground Fault Circuit Interrupter GFCI in circuit it w...

Page 8: ...ir relief valve See filter owner s manual for more details 4 If water source is higher than the pump pump will prime itself when suction and outlet valves are opened If water source is lower than the pump unscrew and remove strainer cover fill strainer housing with water 5 Clean and lubricate strainer cover O ring with Jack s 327 if necessary 6 Replace strainer cover on strainer housing turn clock...

Page 9: ...over from strainer housing See Parts Diagram on page 11 of this manual for pump component locations 3 Disconnect pump from mounting pad wiring after power has been turned OFF and piping 4 Once the pump is removed of water re install the strainer cover and drain plugs Store pump in a dry area Shaft Seal Change Instructions IMPORTANT SAFETY INSTRUCTIONS PLEASE READ AND FOLLOW ALL INSTRUCTIONS When s...

Page 10: ...press it firmly into the recess of the seal plate item 15 with the polished ceramic surface facing out 9 Reassemble the motor to the seal plate item 15 using the four 4 3 8 x 1 bolts item 18 and re attach the motor support item 20 to the seal plate item 15 10 Gently wipe the black polished surface of the spring seal assembly item 13 with a soft cotton cloth 11 Press the spring seal assembly item 1...

Page 11: ...1 2 SPX3200UG Union Gasket 1 3 SPX3200A Pump Strainer Housing 2 x 2 1 2 with Drain Plugs threaded style 1 4 SPX3200DLS Strainer Cover Kit Includes Strainer Cover Lock Ring O Ring 10 SPX3200DLSB Strainer Cover Kit Biguanide Sanitizer Applications Only NOT Pressure Testable 10 5 SPX3200S Strainer Cover O Ring 10 6 SPX3200M Strainer Basket 15 7 SPX3200Z8 Diffuser Screw 1 8 SPX4000Z1 Diffuser O Ring 1...

Page 12: ... 1 16 SPX3200Z211 Housing Insert Seal Plate Spacer Kit 1 17 SPX3200Z3 Housing Bolt 10 18 SPX3200Z5 Motor Bolt 1 19 SPX4000FG Drain Plug with O Ring 10 20 SPX3200GA Bracket Motor Support TriStar 1 21 SPX3200SR Base Tall Riser TriStar 1 Pump SKU Detail Model P N Motor P N Impeller P N SP36075EE SPX3605Z1BER SPX3220C SP36120EE SPX3605Z1BER SPX3230CU STA RITE is a registered trademark of Sta Rite Indu...

Page 13: ... strainer housing is filled with water and cover o ring is clean Ensure o ring is properly seated in the cover o ring groove Ensure o ring sealing surface is lubricated with Jack s 327 and that strainer cover is locked firmly in position Lubricant will help to create a tighter seal 2 Loose connections on suction side Solution Tighten pipe union connections NOTE Any self priming pump will not prime...

Page 14: ...any joint low water level in pool and unrestricted discharge return lines Solution Correct suction condition or throttle return lines if practical Holding hand over return fitting will sometimes prove this point or putting in a smaller eyeball fitting 2 Vibration due to improper mounting etc Solution Mount the pump on a level surface and secure the pump to the equipment pad 3 Foreign matter in pum...

Page 15: ...ing the warranty period except as a result of freezing negligence improper installation use or care shall be repaired or replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays To obtain warranty replacements or repair defective components or parts should be returned transportation paid to the place of purchase or to the nearest authorized...