USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
TriStar Variable Speed Pump
30-LITINSB004 Rev-B
Page 8
Configuration Menu
To ensure that the pump speeds and timers are setup according to the site specific
individual requirements, access the Configuration Menu by
pressing and holding the
DISP/FUNC
button for several seconds untill the ConFg screen appears.
C
V1
V2
V3
Power
F 9
o n
P
V1
V2
V3
Power
0 0
r 2
V1
V2
V3
Power
5 0
1 2
V1
V2
V3
Power
0 0
2 4
h
V1
V2
V3
Power
0 5
0
V1
V2
V3
Power
0 0
3 0
h
V1
V2
V3
Power
0 0
4
The first Configuration Menu screen is used to adjust the
duration of the priming time. Press or hold down either
or arrow button to adjust the run time between zero and
4 minutes. A setting of zero disables the priming cycle. Press
DISP/FUNC
button to advance to next screen.
▲
▼
This screen allows the speed of V1 to be adjusted between
600 rpm and 3000 rpm by pressing or holding down either
or arrow button. Press
DISP/FUNC
button to advance
to the next screen.
▲
▼
This screen allows the speed of V2 to be adjusted between
600 rpm and 3000 rpm by pressing or holding down either
or arrow button. Press
DISP/FUNC
button to advance
to the next screen.
▲
▼
This screen allows the timer of V2 to be adjusted between
5 minutes and 18 hours by pressing or holding down either
or arrow button. Press
DISP/FUNC
button to advance
to the next screen.
▲
▼
This screen allows the speed of V3 to be adjusted between
600 rpm and 3000 rpm by pressing or holding down either
or arrow button. Press
DISP/FUNC
button to advance
to the next screen.
▲
▼
This screen allows the timer of V3 to be adjusted between
5 minutes and 18 hours by pressing or holding down either
or arrow button. Press
DISP/FUNC
button to advance
to the next screen.
▲
▼
Note:
When in configuration mode, the LED for the speed being configured will be constantly “
FLASHING”.
When exiting configuration mode all three of the speed LED’s will
“FLASH”
to signify that all settings have been saved.
If the configuration mode has not been completely exited, after 2 minutes of inactivity the controller will save all of the
settings excluding the current screen settings and exit configuration mode.
Quick Speed Change
Use the and arrow buttons to quickly adjust the current speed that the pump is running at. When a quick speed
change is performed the LED for the changed speed will be
“FLASHING”
. The LED will continue to flash until the speed
is saved, or untill the timer runs out for that speed or the power is cycled to the pump.
The new speed is only saved by pressing simultaneously the and arrow buttons and then the LED for that speed
will illuminate solid.
▲
▲
▼
▼