USA
GB
14
Do not let the beam enter your eye, another person’s eye or the eye of an animal!
This may cause severe eye injuries.
1. Technical Information /
Elements of the Device
• Rapid detection function
• Precise non-contact measurements
• Dual laser sighting
• Automatic Data Hold
• °C/°F switch
• Emissivity digitally adjustable from 0.1 to 1.0
• MAX temperature displays
• Backlight LCD display
• Automatic selection range and Display Reso-
lution 0.1 ºC (0.1 ºF)
• Trigger lock
• Set high and low alarms
Temperature range
- 50 to 550 °C
(- 58 °F ~ 1022 °F)
Display resolution 0.1
°C (0.1 °F)
1 °F
D:S
12:1
< 1.000
> 1.000
Accuracy for targets:
Assumes ambient
operating tempera-
ture of
10 to 50 °C
(50 to 122 °F)
- 50 °C ~ 20 °C
(- 58 °F ~ 68 °F)
20 °C ~300 °C
(68 °F ~572 °F)
300 °C ~550 °C
(572 °F ~ 1.022 °F)
-± 2.5 °C (4.5 °F)
± 1.0 % ± 1.0 °C
(1.8 °F)
± 1.5 %
Measuring
sequence
- 50 ~ 20 °C
(- 58 ~ 68 °F)
20 ~ 550 °C
(68 ~ 1.022 °F)
± 1.3 °C (2.3 °F)
± 0.5 % oder
± 0.5 °C (0.9 °F)
Reaction time
150 ms
Spectral response
8 ~ 14 um
Emissivity
Digitally adjustable
from 0.1 to 1.0
Over range indication LCD will show “----”
Polarity
Automatic (no indi-
cation for positive
polarity)
Minus (-) sign for
negative polarityt
Diode laser
output < 1 mW,
Wavelength
630 ~ 670 nm, Class
2laser product
Operating temp.
0 to 50 °C
(32 to 122 °F)
Storage temp.
– 10 to 60 °C
(14 to 140 °F)
Relative humidity
10 % ~ 90 % RH
operating, < 80 %
RH storage
Power supply
9 V battery, NEDA
1.604 A or IEC 6LR61
or equivalent
Safety
“CE” Comply with
EMC
2. Included
• HAZET Infrared Thermometer
3. Application
CAUTION:
•
Field of View:
Make sure that the target is
larger than the unit’s spot size. The smaller the
target, the closer you should be to it. When
accuracy is critical, make sure the target is at
least twice as large as the spot size
3
Design and Function
-
Summary of Contents for 1991-1
Page 27: ......