9. Application
The container tube can be loaded either by using a
cartridge or with a filler pump or by bulk filling.
Cartridge loading:
• Disconnect applicance from air supply
• To bleed, operate air vent valve
• Remove gun head from container tube by reverse
turn
• Draw back completety the piston rod until you
encounter resistance
• Remove both screw caps of the grease cartridge
• Set in cartridge,
turn it in the direction indicated by the arrow
• Screw together firmly gun head and container
tube
• Press the catch plate and release the piston rod
until you encounter resistance
• To bleed, operate air vent valve
• Screw spout into adapter (thread of screw)
• Connect appliance to air supply
• Grease gun is ready for use - operate trigger
Loading with filler pump:
• Disconnect appliance from air supply
• To bleed, operate air vent valve
• Draw back completely the piston rod until you
encounter resistance
• Put the grease gun with the filler plug onto the
filler pump and start loading.
Attention!
do not oveRloAd GReAse Gun!
• Disconnect grease gun from filler pump
• Press the catch plate and release the piston rod
until you encounter resistance
• To bleed, operate air vent valve
• Screw spout into adapter (thread of screw)
• Connect appliance to air supply
• Grease gun is ready for use - operate trigger
Bulk filling:
• Disconnect appliance from air supply
• To bleed, operate air vent valve
• Remove gun head from container tube by reverse
turn
• Draw back completely the piston rod, fill bulk
grease in empty container tube. Avoid air packets
• Screw together firmly gun head and container
tube
• Press the catch plate and release the piston rod
until you encounter resistance
• To bleed, operate air vent valve
• Screw spout into adapter (thread of screw)
• Connect appliance to air supply
• Grease gun is ready for use - operate trigger
10. Storage
The Grease Gun must be stored as indicated
below:
• Do not store outdoors.
• Store in a dry and dust-free place.
• Do not expose to liquids or aggressive
substances.
• Storage temperature: -10 to +45°C.
• Relative air humidity: 65%.
11. Maintenance and Cleaning
• Do not let fall down. Do not expose to impacts or
liquids as they might affect the functionality and
damage the tool.
• The operator must check regularily the good
working order of all components.
• If the grease gun will not be used for a longer
period of time, disconnect appliance from the air
supply, release piston rod via the catch plate and
bleed the container tube.
223 083