B.10.2
G072 Isolated Digital Event Adapter
l
32 digital event input channels
l
4 digital event output channels
l
230 V RMS event channel isolation
l
Full channel to channel isolation
l
Removable screw terminals for quick cable connections
l
Direct interface to GEN DAQ mainframe event connector
l
GEN DAQ mainframe to adapter cable included
l
No external power supply required
l
Optional cable set to connect to GN6470 or GN4070
The isolated Digital Event Adapter provides an isolation barrier for up to 32
digital event input channels. Furthermore 4 event output channels are available if the adapter is connected to the
Digital Event/Timer/Counter connector of GEN DAQ mainframes. The adapter can optionally be connected directly
to the GEN DAQ Binary Marker Timer/Counter card.
Using the isolated Digital Event Adapter allows the user to avoid ground loops and improves immunity to electrical
noisy environments.
The channel to channel and channel to ground isolation voltage is 230 V RMS. The standard input voltage of 4.5 –
11.5 V for logic “1” can be increased by using external resistors. Therefore higher voltage levels can be used for logic
“0” and “1”.
The wiring of the signal cable is easy due to the pluggable screwed joint connectors of the adapter.
For easy connectivity the adapter is powered by the GEN DAQ mainframe or the GEN DAQ Binary Marker Timer/
Counter card to avoid the need for a separate power supply.
GEN3i
I3763-3.1 en HBM: public
775