Mounting and load application
8
A03009_02_Y00_01
HBM: public
PW25…
3
Mounting and load application
The load cells are firmly clamped at the mounting holes, the load is applied at
the other end. The recommended screws and tightening torques can be found
in the table below:
Version
Thread
Max. thread
reach
Min. property
class
Tightening
Standard
M6
10 mm
8.8
10 N
⋅
m
Rustless
M6
10 mm
A2-70 or A4-70
10 N
⋅
m
1)
Recommended value for the specified property class. Please comply with the screw
manufacturer's instructions with regard to screw dimensions.
Load must not be applied to the side where the cable connection is located, as
this would cause a force shunt.
Load application / platform center
Connection cable
Mounting
Intermediate spacer
Intermediate spacer
min.
4 mm
min.
4 mm