PWSE
8
A3361-1.0 en/de/fr
HBM
2
Conditions on site
The PWSE series load cells reach the protection class IP67.
2.1
Protection against corrosion
The load cells must be protected against chemicals that could attack the
transducer body (stainless) steel or the cable.
NOTE
Acids and all substances that release ions also attack stainless steels and
their welded seams.
Should there be any corrosion, this could cause the transducer to fail. In this
case, appropriate protective measures should be implemented.
2.2
Deposits
Dust, dirt and other foreign matter must not be allowed to accumulate suffi
ciently to divert some of the measuring force onto the housing, thus invalidat
ing the measured value (force shunt).