Function getSystemeventIntCount
This function is only valid in context of a Task > External
Event > System Event. The number of arguments de
pends on the type of the signal determined by the get
SystemeventNr function. This function returns the avail
able number "INT"type arguments for the current
systemevent. Every PMX device carries a xml file de
scribing the valid systemevents to be retrieved via
http://pmx/data/systemevent.xml.
Name
Data type
Inherited
from
Adress
Initial
value
Comment
getSystemeventInt
Count
DINT
Function: GetSystemeventLInt
This function is only valid in context of a Task > External
Event > System Event. The number of arguments de
pends on the type of the signal determined by the get
SystemeventNr function. This function returns the nth
argument of type "LINT" for the corresponding
systemevent. Every PMX device carries a xml file de
scribing the valid systemevents to be retrieved via
http://pmx/data/systemevent.xml.
Name
Data type
Inherited
from
Adress
Initial
value
Comment
getSystemeventInt
INT
idx
DINT
Index value of
the n‐th Int of the
systemevent.
Possible values:
0<=idx<5 and
idx<>
Summary of Contents for PX401
Page 1: ...Operating Manual English PMX...
Page 104: ...Electrical connections PMX 104 A4354 2 2 HBM public PMX...
Page 141: ...Startup PMX A4354 2 2 HBM public 141 Network settings...
Page 239: ...Internal calculation channels PMX A4354 2 2 HBM public 239...
Page 241: ...Internal calculation channels PMX A4354 2 2 HBM public 241...
Page 246: ...Internal calculation channels 246 A4354 2 2 HBM public PMX...
Page 264: ...Internal calculation channels 264 A4354 2 2 HBM public PMX...
Page 272: ...Parameter sets measurement programs 272 A4354 2 2 HBM public PMX...
Page 295: ...Communication with a control system PMX A4354 2 2 HBM public 295...
Page 297: ...Communication with a control system PMX A4354 2 2 HBM public 297...
Page 300: ...Communication with a control system 300 A4354 2 2 HBM public PMX...
Page 376: ...CODESYS V3 Soft PLC WGX001 only 376 A4354 2 2 HBM public PMX...
Page 378: ...CODESYS V3 Soft PLC WGX001 only 378 A4354 2 2 HBM public PMX...
Page 381: ...CODESYS V3 Soft PLC WGX001 only PMX A4354 2 2 HBM public 381...
Page 392: ...CODESYS V3 Soft PLC WGX001 only 392 A4354 2 2 HBM public PMX Dialog Updating the PMX device...
Page 489: ...Object directory PMX A4354 2 2 HBM public 489...
Page 523: ...Diagnosis and maintenance PMX A4354 2 2 HBM public 523 Network settings...