Electrical connections PMX
118
A4354-2.2
HBM: public
PMX
8.7.2
Starting up the TEDS module
Sensors can be fitted with TEDS at the factory and
delivered in the written state.
TEDS modules that are already mounted in the connector
can be subsequently configured and parameterized with
a TEDS dongle (1-TEDS-DONGLE) and a TEDS Editor.
The TEDS Editor
“
scans
“
the TEDS module and indicates
its readiness for programming (also see the HBM
brochure: TEDS data memory in the transducer - content
and data memory editing).
8.7.3
PMX parameterization with TEDS
If a transducer with TEDS is connected, and contains the
parameterization data for a sensor, this can be used to
automatically parameterize the PMX.
The PX455 measurement card has a 0‐wire TEDS. The
sense leads of the sensor cable are used to address the
TEDS chip.
Important
PMX only works with the 2point scaling of the TEDS.
Scalings that have been stored as tables or polynomials
cannot be read in. But an internal calculation channel of
the PMX can be used for this purpose (see Chap. 13).
In the PX401 and PX460 measurement cards, the TEDS
chip is addressed separately via an additional connection
(1‐wire TEDS).
The TEDS functionality can be set by channel in PMX to
determine how PMX should behave after switching on or
plugging in TEDS sensors:
Summary of Contents for PX401
Page 1: ...Operating Manual English PMX...
Page 104: ...Electrical connections PMX 104 A4354 2 2 HBM public PMX...
Page 141: ...Startup PMX A4354 2 2 HBM public 141 Network settings...
Page 239: ...Internal calculation channels PMX A4354 2 2 HBM public 239...
Page 241: ...Internal calculation channels PMX A4354 2 2 HBM public 241...
Page 246: ...Internal calculation channels 246 A4354 2 2 HBM public PMX...
Page 264: ...Internal calculation channels 264 A4354 2 2 HBM public PMX...
Page 272: ...Parameter sets measurement programs 272 A4354 2 2 HBM public PMX...
Page 295: ...Communication with a control system PMX A4354 2 2 HBM public 295...
Page 297: ...Communication with a control system PMX A4354 2 2 HBM public 297...
Page 300: ...Communication with a control system 300 A4354 2 2 HBM public PMX...
Page 376: ...CODESYS V3 Soft PLC WGX001 only 376 A4354 2 2 HBM public PMX...
Page 378: ...CODESYS V3 Soft PLC WGX001 only 378 A4354 2 2 HBM public PMX...
Page 381: ...CODESYS V3 Soft PLC WGX001 only PMX A4354 2 2 HBM public 381...
Page 392: ...CODESYS V3 Soft PLC WGX001 only 392 A4354 2 2 HBM public PMX Dialog Updating the PMX device...
Page 489: ...Object directory PMX A4354 2 2 HBM public 489...
Page 523: ...Diagnosis and maintenance PMX A4354 2 2 HBM public 523 Network settings...