CANBus
CAN LEDs (channel)
Constant green
Channel is ready for operation
Flashing yellow
Firmware download active
Yellow on
Boot process running
Red on
Channel has errors
Ethernet LED (only QuantumX)
Green on
Ethernet link status is OK
Flashing yellow
Ethernet data transmission ongoing
5.2.2
Receiving CAN messages
To be able to receive CAN messages, the node must be
able to identify the relevant messages. This can be done
directly on the node or, in a reproducible way, by previ
ously generated messages in the sensor database. Indi
vidual messages can be linked to the node by dragging
from the sensor database and dropping them where re
quired.
CAN databases type *.dbc can also be read into the
sensor database. If no CAN database is available, it can
also be created. Editors for this purpose are provided by
different companies.
Received CAN messages are instantly "time-stamped" in
measurement mode. This enables directly acquired
measured quantities and CAN messages to be acquired
and analyzed in parallel and synchronously in the entire
system.
Summary of Contents for SOMATXR
Page 1: ...Operating Manual Bedienungsanleitung English Deutsch CANBus...
Page 3: ...Operating Manual Bedienungsanleitung English Deutsch CANBus Receive Transmit...
Page 65: ...QuantumX SomatXR and CCP XCP on CAN CANBus A4461 2 0 HBM public 63...
Page 74: ...QuantumX SomatXR and CCP XCP on CAN 72 A4461 2 0 HBM public CANBus...
Page 75: ...Operating Manual Bedienungsanleitung English Deutsch CANBus Empfangen Senden...
Page 141: ...QuantumX SomatXR und CCP XCP on CAN CANBus A4461 1 0 HBM public 67...
Page 149: ...QuantumX SomatXR und CCP XCP on CAN CANBus A4461 1 0 HBM public 75...
Page 151: ...QuantumX SomatXR und CCP XCP on CAN CANBus A4461 1 0 HBM public 77...