43
T12
A1979
−
10.0 en
HBM
Assignment for plug 5:
CAN Bus; second device plug; A-coded, black washer
Top view
1
2
4
3
5
Binder 713
(M12x1)
Plug
pin
Assignment
Color
code
1
Shield
−
2
Not in use
−
3
CAN ground
−
4
CAN HIGH-dominant high
wh
5
CAN LOW-dominant low
bu
Shielding connected to housing ground
Assignment for plug 5:
PROFIBUS (option); B-coded, violet washer
Top view
1
2
4
3
5
Binder 715
(M12x1)
Plug
pin
Assignment
1
5 V (typ. 50 mA)
2
PROFIBUS A
3
PROFIBUS ground
4
PROFIBUS B
5
Shield
Shielding connected to housing ground
9.4 Supply voltage
The transducer must be operated with a separated extra-low voltage (nominal
(rated) supply voltage 18 to 30 V
DC)
. You can supply one or more torque
flanges within a test bench at the same time. Should the device be operated
on a DC voltage network
1)
, additional precautions must be taken to discharge
excess voltages.
The notes in this section relate to the self-contained operation of the T12
without HBM system solutions.
The supply voltage is electrically isolated from signal outputs and shunt signal
inputs. Connect a separated extra-low voltage of 18 V to 30 V to pin 3 (+) and
pin 2 ( ) of plug 1 or 3. We recommend that you use HBM cable
KAB 8/00
−
2/2/2 and the relevant Binder sockets, that at nominal (rated)