16
HBM T40MS 2020 en (11.03.2020) HBM: public
T40MS without speed measuring system
T40MS with a rotational speed measuring system
Fig. 4.2:
Stator housing and lower antenna segment with antenna wire
1. Undo and remove the bolted connections (M5) on the upper antenna segment.
There are fan type lock washers between the antenna segments: Make sure that they do
not get lost.
2. Use an appropriate base plate to install the stator housing in the shaft train so that there
is sufficient opportunity for horizontal and vertical adjustments. Do not fully tighten the
bolts yet.
Tip
If your transducer has a sensor for the reference signal, you should only fit the
upper antenna segment after step 5.
3. Now use two hexagon socket screws to mount the upper antenna segment removed
in Point 1 on the lower antenna segment.
Make sure that the two fan type lock washers are inserted between the antenna
segments (these ensure that there is a defined contact resistance)!
Stator housing Sensor head for measuring rotational speed
lower antenna segment
Antenna wire