Application
118
A4774-1.0
HBM: public
WTX110
8.2.4
Mode: Inside band (
Inside band
)
Weight
Time
Output
Lower limit
Band span
Lower limit (
Low lim
) / Band span (
Band spn
)
In Inside band mode, Lower limit and Band span define a band. Within that
band, the relevant limit switch status is set. The limit is then likewise set on a
preconfigured digital output (e.g.
output 3 GW1
).
As soon as the level is outside the band again, the limit switch status is reset.
8.3
Configuration Digital I/O (
Digital I/O
)
For more information on the keys necessary to access this menu group, go to
the
.
For the settings in this menu group, the basic precondition is the hardware
presetting of the digital inputs/outputs (
Information
During the configuration the digital I/Os are deactivated.