Supervisormode
134
A4774-1.0
HBM: public
WTX110
10.2.5.1
Upward dosing (
Upwards
)
In upward dosing, the container being filled is weighed during filling. Normally
the container is removed with the fill material when filling is complete.
Tare
Measuring
time
Residual flow
Emptying
Coarse dosing
Fine dosing
Fig. 10.1
Upward dosing
10.2.5.2
Downward dosing (
Downwards
)
In downward dosing, the decrease in weight of a container is measured while
filling a (smaller) container.
Tare
Measuring
time
Residual flow
Filling
Coarse dosing
Fine dosing
Fig. 10.2
Downward dosing