Supervisormode
WTX110
A4774-1.0
HBM: public
135
10.2.6
Tare mode (
Tare mode
)
This tare function is designed specially for batching processes.
Menu
Key
Function/Secondary selection
Tare mode
Off
After starting (RUN command or digital
input or Enter key)
no
taring is carried out.
No
peset tare delay time is waited.
On
If the measurement is lower than the fine
flow cut-off point after starting (RUN com
mand or digital input or Enter key), the tare
delay time is waited, then taring is carried
out. Then the coarse flow phase starts.
10.2.7
Emptying mode (
Emptying
)
Emptying mode can optionally be used to monitor the end of the filling process.
During emptying, a digital output can be activated to control an emptying valve
for example.
Two variants are available:
Menu
Key
Function/Secondary selection
Emptying
Time
Time-controlled emptying.
Only the
Time
parameter determines
the duration of emptying.
You can use the emptying time
parameter (parameter P1 > 0) to
activate emptying.
Weight
Weight-controlled emptying
The Empty weight parameter specifies
the emptying limit. The emptying time
is also used as a maximum duration.
You can use the emptying time
parameter (parameter P1 > 0) to
activate emptying.
Summary of Contents for WTX110
Page 1: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 3: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 10: ...8 A4774 1 0 HBM public WTX110 17 Geo values 212...
Page 217: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 224: ...8 A4774 1 0 HBM public WTX110 17 Geowerte 217...