Supervisormode
152
A4774-1.0
HBM: public
WTX110
Fine flow
Lockout time
Weight
Time
Fig. 10.12 Lockout time for fine flow
10.2.31 Dosing delay 1 (
Dos.delay1(s)
)
The dosing delay time 1 (DL1) starts after the fine flow has been cut off (fine
flow cut-off point). At the end of this delay time 1, dosing delay 2 is started.
This time is signaled on the preconfigured control output (DL1/DL2) as the
delay prior to activation of the output by dosing delay 2 (DL2).
Information
The residual flow status bit is already set during dosing delay time 1, see also
16.2.32 Residuals.
10.2.32 Dosing delay 2 (
Dos.delay2(s)
)
Dosing delay time 2 (DL2) is started after dosing delay 1 ends. At the end of
dosing delay 2 the residual flow time starts.
During the dosing delay time the control output (DL1/DL2) is activated.