The residual flow status bit is already set during dosing delay time 1, see also
16.2.32 Residuals.
10.2.33 Residual flow time (
Residuals
)
The residual flow time starts after the fine flow cut-off point is reached. It
records the residual flow. At the end of this delay time, checkweighing is
carried out.
Recording the residual flow is important for correct measurement of the actual
weight in checkweighing, and so also for optimization where appropriate. The
time to set depends on the dosing device and the settling time of the digital
filter.
10.2.34 Stabilization time (
Stabilizat.(s)
)
After the fill flow phase and residual flow phase comes the stabilization time.
If standstill recognition (MTD) is active, checkweighing is carried out after
standstill, but within the stabilization time. Otherwise checkweighing is started
immediately.
If no standstill occurs within the stabilization time, the actual weight is
measured in any case once the stabilization time expires.
10.2.35 Emptying time (
Empt.time(s)
)
By setting parameter P1 > 0 you activate the emptying time. Emptying starts
immediately after checkweighing. Then the preconfigured control output
(Empty) is activated to carry out emptying, and is automatically switched to the
gross measurement value. Emptying is regarded as complete when the gross
weight in emptying mode is below the empty weight or when the emptying
time (in both emptying modes) is exceeded. If the emptying time is exceeded,
emptying ends, regardless of whether the scale is empty or not. When empty
Summary of Contents for WTX110
Page 1: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 3: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 10: ...8 A4774 1 0 HBM public WTX110 17 Geo values 212...
Page 217: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 224: ...8 A4774 1 0 HBM public WTX110 17 Geowerte 217...