Calibration
188
A4774-1.0
HBM: public
WTX110
The following table lists default values of the
Calibration
group to which
Reset Parameter
resets.
Group
Parameters
Standard
value
Your calibration
1 Scale parameters
Single/dual/triple
range
Single
range
One/two/three
intervals
One interval
Capacity
3000
Interval
1
Unit
kg
2 Calibration
Geo value
20
Zero (mV/V) W1
0.00000
Load (mV/V) W1
2.00000
Zero (mV/V) W2
0.00000
Load (mV/V) W2
2.00000
5 Adaptation
Motion window
0.5D
Motion count(er)
20
Filter size
11
Auto zero range
0.5D
Pushbutton zero (+)
2%
Pushbutton zero (–)
2%
Power-up Zero
OFF
Overload
9D
Incline switch
OFF
NTEP
N
Underload 20d
Y
With taring
Y
Update rate
225
Summary of Contents for WTX110
Page 1: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 3: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 10: ...8 A4774 1 0 HBM public WTX110 17 Geo values 212...
Page 217: ...Operating Manual Bedienungsanleitung English Deutsch WTX110...
Page 224: ...8 A4774 1 0 HBM public WTX110 17 Geowerte 217...