Mechanical installation
Z16A
A04000_03_Y00_00
HBM: public
11
6
Mechanical installation
6.1
Important precautions during installation
S
Handle the transducer with care.
S
Welding currents must not be allowed to flow over the transducer. If there is
a risk that this might happen, you must provide a suitable low-ohm
connection to electrically bypass the transducer. HBM, for example,
provides the highly flexible EEK ground cable, which can be screwed on
above and below the transducer.
S
Make sure that the transducer cannot be overloaded.
S
The optional cable with an outer braided wire covering for the configurable
K-Z16A3 with option 20R, is intended for use when there is increased
mechanical stress (e.g. damage caused by gnawing rodents). If this cable is
used, the outer braided wire has to be connected to potential equalization at
least once, to avoid accidental energization. This outer braided wire is not
used to shield the load cell. The inner braid of the load cell cable is used for
shielding (also refer to 7.6 EMC protection).
WARNING
There is a danger of the transducer breaking if it is overloaded. This can cause
danger for the operating personnel of the system in which the transducer is
installed.
Implement appropriate safety measures to avoid overloads or to protect
against the resulting dangers.
Notice
Load cells are precision measuring elements and need to be handled carefully.
Dropping or knocking the transducer may cause permanent damage. Make
sure that the transducer cannot be overloaded, including while it is being
mounted.
Summary of Contents for Z16A
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 25: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 47: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 70: ...Dimensions 24 A04000_03_Y00_00 HBM public Z16A...
Page 71: ...Dimensions Z16A A04000_03_Y00_00 HBM public 25...