Specifications
Z16A
A04000_03_Y00_00
HBM: public
19
Type
Z16AC3
Z16AD1
Nominal (rated) load
15
20
15
7.5
t
E
max
Limit load
E
L
% of
E
max
150
Breaking load
E
d
> 350
Relative permissible oscillatory
stress (oscillation width as per
DIN 50100)
F
srel
70
Nominal (rated) displacement at
E
max
, approx.
s
nom
mm
0.20
0.27
0.27
0.20
0.27
Weight without cable, approx.
G
kg
2.3
Degree of protection per DIN EN 60529
(IEC 529)
IP68 (test conditions: 100 hours
under 1m water column);
IP69 K (water at high pressure,
steam cleaner)
Cable length, six‐wire configuration
12m
Material:
Measuring body + housing
Cable entry
Seal
Cable sheath
Stainless steel
Stainless steel
Viton
®
Thermoplastic elastomer
1)
As per OIML R60, with P
LC
= 0.7.
2)
Sensitivity and output resistance are matched in such a way on each transducer that the
measured value lies within the permissible error limits when they are connected in parallel.
3)
The values for non‐linearity (
d
lin
), relative reversibility error (
d
hy
) and temperature coefficient of
sensitivity (
TC
S
) are recommended values. The sum of these values is within the cumulative error
limits according to OIML R60.
4)
Based on DIN 40050, Part 9 specifications, for road vehicles.
5)
As per EN 10088-1.
Summary of Contents for Z16A
Page 1: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 3: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 25: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 47: ...Operating Manual Bedienungsanleitung Manuel d emploi English Deutsch Fran ais Z16A...
Page 70: ...Dimensions 24 A04000_03_Y00_00 HBM public Z16A...
Page 71: ...Dimensions Z16A A04000_03_Y00_00 HBM public 25...