Electrical connection
Z6R…
A4514-1.0
HBM: public
13
5
Electrical connection
The following can be connected for measurement signal
conditioning:
S
carrier-frequency amplifiers
S
DC amplifiers
designed for strain gauge measurement systems.
The load cells are delivered with a six-wire configuration.
5.1
Connection in six-wire configuration
white
black
gray
Excitation voltage (+)
green
red
Shielding/drain wire,
connected to housing
Excitation voltage (-)
Sense lead (-)
Measurement signal (+)
blue
Sense lead (+)
Measurement signal (-)
Fig. 5.1
Pin Assignment
With this connector pin assignment, the output voltage at
the measuring amplifier is positive when the transducer is
loaded.