Display: 3 ¾ digits LCD with a
max. reading of 4000.
Auto range / manual range control.
Polarity: Automatic negative polarity indication.
Automatic zero adjustment.
Overrange indication: The “OL” or “-OL” display.
Low battery indication: Display “ “ sign.
Data Hold: Display “H” sign.
Relative measurement: Display “ “ sign.
Clamp opening size: 32 mm.
Auto Power OFF: When measurement exeeds 10 min. without switching mode and pressing key,
the meter will switch to standby mode. Press any key or switch selector switch to exit standby mode.
When restarting the system, press and hold “select” key to disable auto power off.
Safety standards: EMC/LVD The meter is up to the standards of IEC1010 Double insulation,
Pollution Degree 2, Overvoltage Category III.
Operating enviroment: 0-40°C (32-104°F) Humidity 80% RH.
Storage enviroment: -20 - 60°C (-4 - 140°F) Humidity 90% RH.
Battery: 9 V.
Dimensions: 215 (H) x 84 (W) x 45 (D) mm.
Weight: 335 g. (incl. battery).