Just one key selects the measurement function
“Just one key selects the measurement function” mode happens if SELECT key is pressed
when “SCAn” appears in the LCD. Continuously press this key, the Digital multimeter will exit
the status of auto selection and then enter the specific measure mode DCV, ACV, OHM, Diode,
Continuity, Capacity, SCAN can be selected in turn.
DC and AC Voltage measurement
• Connect the black test lead to “COM” socket and red test leads to the “VΩHz” socket.
• Press SELECT key to “DCV” or “ACV” position.
• Connect the probes across the source or load under measurement.
Resistance measurement and Diode, Continuity Test
• Connect the black test lead to “COM” socket and red test leads to the “VΩHz” socket.
• Press SELECT key to “Ω” or “ ”, “ ” position.
• Connect the probes across circuit to be tested.
Caution: Ensure that the circuit to be tested is “dead”.
Capacitance measurement
• Before testing, discharge the capacitor by shorting its leads together. Use caution in
handing capacitors because they may have a charge on them of considerable power
before discharging.
• Connect the black test lead to “COM” socket and red test leads to the “VΩHz” socket.
• Press SELECT key to “nF” position.
• Connect the probes across capacitor to be tested.
Note: When testing 1000 µF capacitor, note that there will be approx. 15 sec. time lag.
Auto Power-Off
• If the whirl or keys of the meter is no action within certain time, the system will be power
off automatically (sleep mode). It’s 10 minutes to auto power off. In “Auto Power-Off” status,
pressing the function key or enable the function switch, the meter will “Auto Power-On”
(Operation Mode).
• To press and hold any key to power on, “Auto Power-Off” function will be disabled.
Maintenance
• Clean the case with a damp cloth and detergent. Do not use abrasives or solvents.
Battery and fuse replacement
• If the battery is weak, a “ “ symbol will appear on the left of the display. It means that
the battery should be replaced.
2 batteries Cargo 200739 - AA 1.5 V.