background image

ADA 100

® 

Emergency Call System

Housing Devices, Inc.

Page 

8

Medford, MA  02155

Copyright © 1998

800-392-5200

Control Board

The Control Board is located in the Relay Card Cabinet and provides electronic support for
the Master Station and Battery Backup System.  One Control Board is used per system.

Battery Backup System Cabinet

The standard Battery Backup System Cabinet houses the components that encompass the
Battery Backup System, which provides 24VDC continuous power to the ADA 100
Emergency Call System in the event of a power failure.  The system monitors for AC
power failure, AC and DC surge suppression, and no/low battery indications.  It features
auto-resetting overload protection, visual AC and DC power indicators and built-in battery
charger circuitry.  The system includes two 12VDC sealed lead acid batteries (rated @ 4.5
amp hours each), 1.0 amp battery charger, 24VAC 20VA transformer, and has a
continuous output current of 800mA.  UL listed Battery Backup Systems are supplied if
specified.

Amplifier

The Housing Devices ADA-35 Amplifier, powered by 24VDC, located in the Battery
Backup System Cabinet processes the audio communications for the entire system.

NOTE: If the system is connected to an annunciator or fire alarm system, or other auxiliary
power, and an independent Battery Backup System is not utilized, then a separate
Amplifier Cabinet (12” x 12” x 4”) is utilized.

Braille Instructional Sign

The Braille Instructional Sign is framed in an 18 gauge stainless steel frame with Tamper
Proof hardware.  It is to be placed next to each Area Station in the system.  The caption is
written in English and Braille and states: “FOR ASSISTANCE PUSH 3 INCH HELP
BUTTON”.

Illuminated Area Station Sign

An optional illuminated sign with universal mounting hardware is placed above each Area
Station for easy visual identification of the Area Station’s location.  Illuminated signs are
available with or without their own independent battery backup system.

Summary of Contents for ADA 100

Page 1: ...OPERATIONS INSTALLATION GUIDE ADA 100 EMERGENCY CALL SYSTEM VERSION 5 1a JUNE 1998 HOUSING DEVICES INC 407 R MYSTIC AVE MEDFORD MA 02155 800 392 5200 ...

Page 2: ...ET Page 7 RELAY CARD Page 7 CONTROL BOARD Page 8 BATTERY BACKUP SYSTEM CABINET Page 8 AMPLIFIER Page 8 BRAILLE INSTRUCTIONAL SIGN Page 8 ILLUMINATED AREA STATION SIGN Page 8 INSTALLATION Page 9 UNPACKING Page 9 BACK BOX Page 9 SURFACE MOUNTING COLLAR Page 10 MASTER STATION Page 10 AREA STATION Page 10 RELAY CARD CABINET Page 10 BATTERY BACKUP SYSTEM CABINET Page 10 INSTRUCTIONAL SIGNS Page 10 SYST...

Page 3: ...stem incorporates state of the art design developed from years of actual field experience installing over 1 000 devices at hundreds of sites The ADA 100 is a hard wired system that can be operated independently of any other building systems or interfaced with your existing annunciator or fire alarm system It is easy to install and designed to provide you with years of trouble free use with virtual...

Page 4: ...e specific TALK and LISTEN metal buttons identified for each Area Station location in the system Operation of the system is confirmed at both the Master Station and Area Stations by means of audio and visual indicators These indicators verify to the security attendant that the system is fully operational They identify locations requesting assistance alert the security attendant to respond to the r...

Page 5: ... screw plug in connectors to simplify and expedite installation The system s independent supervision helps to promote easy trouble shooting via rapid problem identification and repair The ADA 100 self identifies system problems using its supervisory circuits to illuminate amber colored trouble LEDs located at the Master Station for each independent Area Station location that is affected If a syste...

Page 6: ... up or ON The ON position of the key switch is the only position in which the key may be removed If a fault occurs the system is designed to stay on line and continue to provide emergency call capability from each Area Station without the system needing to be RESET Area Station Indicators and Controls The Area Station communicates directly with the Master Station Depressing the 3 PUSH FOR HELP but...

Page 7: ...er Master Station dimensions A Master Station can accommodate up to 60 Area Stations The baseline Master Station accommodates 1 5 Area Stations The next larger size Master Station accommodates 6 10 Area Stations The next larger size Master Station accommodates 11 15 Area Stations then 16 20 Area Stations and so forth up to 60 Area Stations Multiple Master Stations may be used to accommodate larger...

Page 8: ... 20VA transformer and has a continuous output current of 800mA UL listed Battery Backup Systems are supplied if specified Amplifier The Housing Devices ADA 35 Amplifier powered by 24VDC located in the Battery Backup System Cabinet processes the audio communications for the entire system NOTE If the system is connected to an annunciator or fire alarm system or other auxiliary power and an independe...

Page 9: ...uring shipping must immediately be reported to the carrier and also reported to the Manufacturer within 7 days for damage assessment and potential repair Prior to handling any electronic components on cold dry days the installer shall discharge any collected static electricity to a known ground in order to prevent damage to the ADA 100 system logic by a static discharge Avoid touching board compon...

Page 10: ... to the Master Station as indicated see Master Station Hook Up Diagram Appendix Page 2 slide the unit onto the Back Box or Surface Mounting Collar and attach with the four 4 Tamper Proof screws provided Area Station 1 Use the four 4 manufacturer supplied Tamper Proof screws to attach the Area Station to the previously installed Back Box or Surface Mounting Collar 2 The Area Station shall be locate...

Page 11: ... from water and excess moisture 2 Conduit placement shall be separate from other circuitry to minimize interference with ADA 100 audio communications e g fluorescent lighting 3 Each Area Station will be connected with 4 twisted pair 18AWG with overall shield 4 Make sure shields are clipped short and insulated with electrical tape to prevent possible accidental conduction Consult the Area Station H...

Page 12: ...tput Terminal and Terminal at the same time The meter should read 24VDC standard operating power throughout the ADA 100 Emergency Call System 3 Select the DC setting on a Multi meter and check to see that DC power is present at the Relay Card Cabinet Control Board Terminals 1 and 2 by measuring across Control Board Terminal 1 and Control Board Terminal 2 at the same time The meter should read 24VD...

Page 13: ... Battery Backup Cabinet The other end of the shielded cable must be clipped short and taped to insulate it to prevent accidental conduction If there is no communication between the Master Station and an Area Station s Note If the respective Relay Card is latched in the HELP REQUESTED mode when the Area Station is activated HELP REQUESTED LED is illuminated and does not latch in the HELP COMING mod...

Page 14: ...ing section 4 If SCR replacement does not work please call the Manufacturer Note The area Relay Card is working properly if all the above items check out as described SCR REPLACEMENT Each area Relay Card has a removable SCR chip on it located just below the relays It is different from the jumper also located on the area Relay Card between the relays and the terminal connector Two spare SCR chips a...

Page 15: ...ADA 100 Emergency Call System Housing Devices Inc Page 15 Medford MA 02155 Copyright 1998 800 392 5200 APPENDIX ...

Reviews: