6 Using the heating system – Structure of the menus
130
7 - D
ELIVERY
SYSTEM
6-15
Cleaning
Monitor
cleaning system
( 6)
6m
•
Monitoring of the cleaning system functions
The monitoring limit switch of the cleaning system must
trigger within this set time.
(0 - 180 m)
6-16
Cleaning
Empty ash box
after stoker runtime
( 0)
0h
•
Emptying the ash box
The delivery auger runtime after which the message
“Empty ash box” is displayed. The setting of 0 switches off
the message function. (0 - 200 h)
6-17
Cleaning
Enable times
On 00:00 On 00:00
Off 24:00 Off 00:00
•
Enable cleaning
Time block: Various enabling times can be programmed.
No.
Display
Description
Table 6/8 - System level / 6 - Cleaning
No.
Display
Description
7-01
Delivery type
Variant 1
Variant 2
Variant 3
Variant 4
Variant 5
•
Type of delivery system
1: Flexi-blade or hinged arm delivery system
2: Delivery and conveyor auger
3: Delivery system, intermediate container and dosage
auger
4: Silo delivery system, intermediate container and
dosage auger
5: Pellet vacuum delivery pellet vacuum contai-
ner
7-02
Feeding system
Continuous running
Cycles
•
Feeding system
Setting option for continuous running or clocked cycles
(together with the dosage auger).
7-03
Delivery system
Feeding system
reverse current
( 3.0)
3.0A
•
Feeding system
After exceeding the set motor current, the motor reverses
up to three times. Then a fault message is issued. (0.1 -
10.0 A)
7-04
Delivery system
Response delay
Reversing
( 1)
1s
•
Delivery system/feeding system
Delay time in the event of overcurrent at the drives to
reverse of the rotational direction.
(1 - 9 s)
7-05
Delivery system
Feeding system
reverse runtime
( 1)
1s
•
Feeding system
Reverse running time when the set reverse current is
exceeded.
(0 - 3 s)
Table 6/9 - System level / 7 - Delivery system
Summary of Contents for Compact 25
Page 1: ...hdg bavaria com HDG Compact 25 80 Operation Manual ...
Page 2: ......
Page 186: ...12 Index 186 HDG Compact 25 35 Version 2 de HDG Bavaria GmbH Oktober 2007 ...
Page 187: ......