3 Mode of operation – Overview
19
HDG C
OMPACT
45/50/65/80,
BACK
SIDE
1 Connection of immersion sleeve for thermal safety device (DN 15,
inside thread)
2 Safety heat exchanger connections (DN 15, outside thread)
3 Main switch
4 Ignition fan
5 Pressure equalisation hose
6 Combustion fan
7 Servo motor for primary air
8 Ash removal motor
9 Grate tilting motor
10 Servo motor for secondary air
Figure 3/4 - HDG Compact 45/50/65/80 boiler back side
1
8
7
6
3
2
9
4
5
10