4 Planning and installation – Connections
49
D
IMENSIONS
ON
FLUE
PIPE
SIDE
, HDG C
OMPACT
25/35
1 Boiler supply connection (DN 32, inside thread)
2 Flue gas fan
3 Flue pipe connection Ø 150 mm
4 Boiler return connection (DN 32, inside thread)
5 Filling / draining connection (DN 15, inside thread)
Figure 4/8 - Dimensions on flue pipe side HDG Compact 25/35
B
F
G
H
I
J
A
1
4
E
D
C
5
2
3
1
5
4
3
2
Model
A
B
C
D
E
F
G
H
I
J
HDG Compact 25/35
1174
1064
820
340
312
235
371
466
510
680
Table 4/3 - Dimensions on flue pipe side, HDG Compact 25/35 (mm)