7 Cleaning and servicing the heating system – Requirements
84
4.
Open the front door (1) of the boiler.
5.
Open the combustion chamber door (2).
6.
Inspect the grate (3) for encrustations of cinder or foreign bodies.
7.
Remove any encrustations with a suitable cleaning tools or empty
the grate in manual operation.
✎
See the “HDG Control” operating manual, chapter “6 Parameter
HDG Compact 25 - 80” section “6.2 Boiler” paragraph “Test”.
8.
After cleaning, close the combustion chamber door (2) and the
front door (1) of the boiler.
9.
Re-starting the heating system.
✎
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.2 Switching on the heating system”.
✓
The tilting grate is cleaned.
C
HECKING
AND
EMPTYING
THE
ASH
CONTAINER
Figure 7/4 - Cleaning the tilting grate
3
2
1
Important!
✎
Observe the “Generally applicable safety instructions” in this sec-
tion.
Caution!
Danger of fire from combustion residues
Hot combustion residues can lead to a fire.
Allow the ash to cool and place it only in a suitable fireproof con-
tainer.