7 Cleaning and servicing the heating system – Requirements
101
C
HECKING
THE
FUEL
STORAGE
1.
Switch the heating system off.
✓
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.3 Switching off the heating system”.
2.
Turn the main switch off.
3.
Open the access hatch.
4.
Inspect the fuel storage dust residues or foreign bodies and re-
move these if necessary.
5.
Check the fuel delivery mechanism for wear or damage.
6.
Close the access hatch.
7.
Re-starting the heating system.
✎
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.2 Switching on the heating system”.
✓
The inspection of the fuel storage is completed.
Important!
✎
Observe the “Generally applicable safety instructions” in this sec-
tion.
Caution!
Risk of injury from automatically driven components
When the heating system is turned on, the delivery auger rotates in
the fuel storage. Hands and feet could thereby be crushed.
Switch the heating system off before you enter the fuel storage.
Read the signage and follow the instructions of the official safety or-
ganisations. If no signage is visible contact the installation com-
pany.