4 Planning and installation – Structural requirements
25
*does not apply in connection with HDG automatic ignition system / automatic
cleaning system
Figure 4/2 - Required room sizes and minimum clearances
G
F
C
B
A
E
D
HDG F20/25/30
HDG F40/50
A
at least 300 mm
at least 300 mm
B
at least 100 (or 600) mm
at least 100 (or 600) mm
C
at least 600 (or 100*) mm
at least 600 (or 100*) mm
D
800 mm
800 mm
E
660 mm
760 mm
F
at least 2200 mm
at least 2300 mm
G
at least 1400 mm
at least 1500 mm
Minimum ceiling height
1900 mm
2000 mm
Recommended room height
2300 mm
2300 mm
min. installation dimensions
(without cladding and
attachments)
1025 x 650 x 1585 mm
1075 x 750 x 1645 mm
Table 4/2 - Room sizes and minimum clearances