7 Cleaning and servicing the heating system – Procedure
67
C
LEANING
TOOLS
1 Brush handle
2 Cleaning brush
3 Scraper
4 Ash shovel
5 Wall holder
C
LEANING
THE
FUEL
CHAMBER
AND
SECONDARY
AIR
OPENINGS
1.
Allow the fire in the boiler to burn out and cool off.
1.
Press the
Reload
button on the HDG Control Touch control unit.
2.
The
Fill up / Reload
window appears in the display.
3.
Confirm your entry by pressing the
Confirm
button.
✓
The
Do not open fuel chamber door
message appears in the display.
✓
The flue gas fan is running.
4.
Wait until the progress bar is full.
✓
The
Open fuel chamber door to safety position
message appears in
the display.
5.
Open the fuel chamber door to the safety position.
6.
Wait until the progress bar is full.
✓
The
Open fuel chamber door slowly
message appears in the display.
Figure 7/1 - Cleaning tools
2
3
1
4
5
Important!
✎
Observe the “Generally applicable safety instructions” in this
section.
Summary of Contents for F20
Page 1: ...hdg bavaria com HDG F20 25 30 HDG F40 50 Operating manual ...
Page 2: ......
Page 87: ......